Ex Security Sensor for Zone 1, 21
EX STM 295 Security Sensor
- Areas Ex 1 and 21
- Plastic housing
- Connection room
- Unlocking by undervoltage or off-peak
- Two Ex switch inserts in a case
- Double insulation
- Maintenance force 1000 N
- 90° rotated actuator available on request
- Also available in special version for zone 2 Gases or 22 Dusts
- Please indicate necessary international approvals!
Security policy
Delivery policy
EX safety sensors are used to monitor the position of sliding, swivel or removable protectors. For safety functions according to DIN VDE 0660-209, the devices shall be used only with a PL door monitoring module ""e" according to EN ISO 13849-1 or up to SILCL 3 in accordance with EN 62061.
Data sheet
- Certificate(s)
- BVS 10 ATEX E 053 X, Iecex BVS 11.0030X
- Degree of protection
- IP64
- Ambiant temperature
- -20°C to +55°C
- Power consumption (W)
- 2.5 VA (continuous operation) max. 47 VA (for 250 ms)
- Cable entries
- 2 x M20 x 1.5 (incl. 1 tattoo press)